IBM 7RY 사용자 설명서

다운로드
페이지 226
 
 Symptom-to-FRU index
 153
Error symptoms
264-XXX-0NN 
 (NN = SCSI ID 
of failing Tape Drive)
1.
Tape Cartridge, if user executed the Read/Write Tape 
Drive test (XXX = 256)
2.
SCSI or power cable connected to the tape drive with 
SCSI ID NN
3.
Tape drive with SCSI ID NN – refer to Help and 
Service Information appendix of tape drive’s User 
Guide.
4.
I/O Legacy Board or SCSI Controller – run SCSI 
Controller diagnostic to determine of SCSI bus is 
functioning properly.
264-XXX-999 
 (Errors on 
multiple tape drives, see error 
text for more info)
1.
See error messages/text in the PC Doctor error log for 
detailed information on each individual tape drive 
error.
301-XXX-000
  (Failed Keyboard 
test)
1.
Keyboard
405-XXX-000 
 (Failed Ethernet 
test on controller on the I/O 
Legacy Board)
1.
Verify that Ethernet is not disabled in BIOS.
2.
I/O Legacy Board
405-XXX-00N
   (Failed Ethernet 
test on adapter in PCI slot N)
Note:
Insure modem is 
present and attached to 
server.
1.
Adapter in PCI slot N.
2.
I/O Legacy Board
415-XXX-000  
(Failed Modem 
test)
1.
Cable
2.
Modem
3.
I/O Legacy Board
Error Symptom
FRU/Action
CD is not working properly.
1.
Clean the CD.
2.
Run CD-ROM diagnostics.
3.
CD-ROM Drive
CD-ROM drive tray is not 
working.
 (The server must be 
powered-on.)
1.
Insert the end of a paper clip into the manual tray-
release opening.
2.
Run CD-ROM diagnostics.
3.
CD-ROM Drive
CD-ROM drive is not recognized.
1.
Run Configuration/Setup, enable primary IDE 
channel.
2.
Check cables and jumpers.
3.
Check for correct device driver.
4.
Run CD-ROM diagnostics.
5.
CD-ROM drive
6.
I/O Legacy Board
Error Code/Symptom
FRU/Action