Hardware Maintenance Manual: xSeries 250
 
 
NDIS 4.0 (Windows NT) driver messages
This section contains the error messages for the NDIS 4.0 drivers.  The explanation 
and recommended action are included with each message.
PCNTNW-NW-
091
The hardware configuration conflicts.
Explanation:
 You tried to load a new frame type for the existing 
controller. The hardware assumptions made in doing so are incorrect. 
This error can also occur if you try to specify a mode (such as, 
redundancy) that conflicts with another specified mode.
Action:
 Make sure that your hardware configuration matches the 
software settings.
PCNTNW-NW-
126
The group bit in the node address override was cleared.
Explanation:
 The IEEE address has a group bit that indicates that an 
address belongs to a group of stations. This bit is used only as a 
destination address; it cannot be used as a source address. You tried to 
enter a source address with this bit set. The driver cleared the group bit 
of the source address.
Action:
 None necessary, message is for information only.
PCNTNW-NW-
127
The local bit in the node address override was set.
Explanation:
 The local bit in the IEEE address format indicates that the 
addresses are being managed locally. If you use the node address 
override capabilities of this driver to enter a new address, the local bit 
must be set. You entered an address without the local bit set. The driver 
has set the local bit.
Action:
 None necessary, message is for information only.
PCNTNW-NW-
164
The device was not found.
Explanation:
 The driver cannot find an Ethernet controller in the server.
Action:
  Verify that the Ethernet controller is enabled. If the Ethernet 
controller is enabled, go to “Starting the diagnostic programs” on page 
26 t
o run the diagnostic programs.
PCNTNW-NW-
165
The device was not found at IOADDRESS.
Explanation:
 The Ethernet controller cannot be found at the I/O address 
specified.
Action:
  The Ethernet controller does not require a parameter for the I/O 
address. Remove the I/O address parameter.
PCNTNW-NW-
167
PCI scan specified, device not found.
Explanation:
 The driver cannot locate the Ethernet controller on the PCI 
bus.
Action:
  Verify that the Ethernet controller is enabled. If the problem 
persists, go to “Starting the diagnostic programs” on page 26 to run the 
diagnostic programs.
PCNTNW-NW-
180
The DMA parameter is not necessary for PCI device.
Explanation:
 The Ethernet controller does not require a DMA setting.
Action:
  None necessary, message is for information only.
Table 3. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet 
controller.