 80
Hardware Maintenance Manual: xSeries 250
 
 
Your server contains hardware that enables you to replace a failed hard disk drive 
without turning off the server.  Therefore, you have the advantage of continuing to 
operate the system while a hard disk drive is removed or installed.  These drives are 
known as hot-swap drives.
Each hot-swap drive has two indicator lights on the front of the server.  If the amber 
hard-disk status light for a drive is lit continuously, that individual drive is faulty and 
needs to be replaced.  When the hard-disk status light indicates a drive fault, you can 
replace a hot-swap drive without turning off the server.
Each hot-swap drive that you plan to install must be mounted in a hot-swap-drive 
tray.  The drive must have a single connector attachment (SCA) connector.  Hot-swap-
drive trays come with hot-swap drives.
Internal drive bays
Internal drives are installed in bays.
Your server comes with one CD-ROM drive and one 3.5-inch, 1.44 MB diskette 
drive.
The left front bays support 5.25-inch, half-high, removable-media drives.  Any 
two adjacent 5.25-inch, half-high bays can be converted to a single full-high bay.  
Note:
The server EMI integrity and cooling are both protected by having the left 
front bays covered or occupied.  When you install a drive, save the filler 
panel from the bay, in case you later remove the drive and do not replace it 
with another.
You cannot install hard disk drives in the left front bays.  You can install hot-swap 
hard disk drives only in the hot-swap hard disk drive bays on the right front side 
of the server.
If you are installing a device with a 50-pin connector in one of the left front bays, 
you will need a 68-to-50-pin converter (option number 32G3925).
Your server supports ten 1-inch (26 mm) slim-high, 3.5-inch hot-swap hard disk 
drives in the hot-swap bays.
Hot-swap hard
disk drive bay
Media bays 1 and 2
3.5-inch diskette drive
CD-ROM drive