IBM 61Y 사용자 설명서

다운로드
페이지 226
 
 Symptom-to-FRU index
 155
POST error codes
In the following error codes, X can be any number or letter.
On
Off
Standby mode or dc 
problem.
1.
Move jumper on J23 to pins 2-3 to 
bypass power control.  If the DC 
Good LED comes on, press 
Ctrl+Alt+Delete.  Watch the screen 
for any POST errors.  Check the 
System Error Log for any listed 
problems.                                              If 
the system powers up with no 
errors: 
a.
Power Switch Assembly
2.
Remove the adapters and 
disconnect the cables and power 
connectors to all internal and 
external devices.  Power-on the 
system.  If the DC Good LED 
comes on, replace the adapters and 
devices one at a time until you 
isolate the problem.
3.
Power Supply
4.
Power Backplane
5.
I/O Legacy Board
6.
Processor Board
On
On 
Power is OK.
N/A
Error Code/Symptom
FRU/Action
062 
 (Three consecutive boot 
failures using the default 
configuration.)
1.
Run Configuration/Setup
2.
Battery
3.
I/O Legacy Board
4.
Processor/PCI Board
5.
Processor
101, 102
  (System and processor 
error)
1.
I/O Legacy Board
2.
Processor/PCI Board
106
  (System and processor error) 1.
I/O Legacy Board
2.
Processor/PCI Board
111
  (Channel check error)
1.
Failing adapter
2.
DIMM
3.
I/O Legacy board
114
  (Adapter read-only memory 
error)
1.
Failing adapter
2.
Run diagnostics
AC Good 
LED
DC Good 
LED
Description
FRU/Action