Hardware Maintenance Manual: xSeries 250
Temperature error messages
Fan error messages
Message
Action
DASD "X" Over Temperature
(level-
critical; Direct Access Storage Device bay
"X" was over temperature)
"X" was over temperature)
1.
Ensure system is being properly cooled
;
DASD Over recommended Temperature
(sensor X) (level-warning; the DASD
backplane had an over temperature
condition)
backplane had an over temperature
condition)
1.
Ensure system is being properly cooled
;
DASD under recommended temperature
(sensor X) level-warning; the DASD
backplane had an under temperature
condition)
backplane had an under temperature
condition)
1.
Ambient temperature must be within
normal operating specifications
normal operating specifications
; (see
Power Supply "X" Temperature Fault
(level-critical; power supply "x" had over
temperature condition)
temperature condition)
1.
Ensure system is being properly cooled;
see “Temperature checkout” on page 32.
see “Temperature checkout” on page 32.
2.
Replace Power Supply "X"
System board is over recommended
temperature
temperature
(level-warning; system board
is over recommended temperature)
1.
Ensure system is being properly cooled;
2.
Replace system board
System board is under recommended
temperature
temperature
(level-warning; system board
is under recommended temperature)
1.
Ambient temperature must be within
normal operating specifications
normal operating specifications
; (see
System over temperature for CPU "X"
(level-warning; CPU "X" reporting over
temperature condition)
temperature condition)
1.
Ensure system is being properly cooled;
2.
Replace CPU "X".
3.
Replace Processor/PCI Board.
System under recommended CPU "X"
temperature
temperature
(level-warning; system
reporting under temperature condition for
CPU "X")
CPU "X")
1.
Ambient temperature must be within
normal operating specifications
normal operating specifications
; (see
2.
Replace CPU "X".
3.
Replace Processor/PCI Board.
Message
Action
Fan "X" failure
(level-critical; fan "X" had a
failure)
1.
Check connections to fan "X"
2.
Replace fan "X"
Fan "X" fault
(level-critical; fan "X" beyond
recommended RPM range)
1.
Check connections to fan "X"
2.
Replace fan "X"