IBM 61Y 사용자 설명서
Diagnostics
23
Rebuilding a defunct drive
A physical drive is defunct when there is a loss of communication between the
controller and the physical drive. This can be caused by any of the following:
controller and the physical drive. This can be caused by any of the following:
•
An improperly connected cable, physical drive, or controller
•
A loss of power to a drive
•
A defective cable, backplane, physical drive or controller
07
6C
Explanation:
Online/rebuild and ready/standby drives are not
responding, a drive was found at the incorrect SCSI ID, and
unidentified drives were found.
unidentified drives were found.
Action:
Press F4, F5, F6, or F10.
07
78
Explanation:
Online/rebuild, ready/standby, and hot-
spare/standby hot-spare drives are not responding, and
unidentified drives were found.
unidentified drives were found.
Action:
Press F4, F5, or F10.
07
7C
Explanation:
Online/rebuild, ready/standby, and hot-
spare/standby hot-spare drives are not responding, a drive was
found at the incorrect SCSI ID, and unidentified drives were
found.
found at the incorrect SCSI ID, and unidentified drives were
found.
Action:
Press F4, F5, F6, or F10.
09
00
Explanation:
No error occurred.
Action:
No action is required.
09
10
Explanation:
Hot-spare/standby hot-spare drives are not
responding.
Action:
Press F4, F5, or F10.
09
20
Explanation:
Ready/standby drives are not responding.
Action:
Press F4, F5, or F10.
09
30
Explanation:
Hot-spare/standby hot-spare and ready/standby
drives are not responding.
Action:
Press F4, F5, or F10.
0F
00
Explanation:
No error occurred.
Action:
No action is required.
0F
10
Explanation:
Hot-spare/standby hot-spare drives are not
responding.
Action:
Press F4, F5, or F10.
0F
20
Explanation:
Ready/standby drives are not responding.
Action:
Press F4, F5, or F10.
0F
30
Explanation:
Hot-spare/standby hot-spare and ready/standby
drives are not responding.
Action:
Press F4, F5, or F10.
BCS
ECS
Explanation and possible recovery action