 Diagnostics
 29
Diagnostic panel LEDs
The following illustration shows the LEDs on the diagnostics panel inside the server.  
See Table 1 on page 31 for information on identifying problems using these LEDs.  
Light path diagnostics
You can use the light path diagnostics built into the server to quickly identify the type 
of system error that occurred.  The server is designed so that LEDs remain illuminated 
when the server shuts down, as long as the power supplies are operating properly.  
This feature helps you to isolate the problem if an error causes the server to shut 
down.
If the system error LED (on the information LED panel) is not lit and no diagnostics 
panel LEDs are lit, it means that the light path diagnostics have not detected a system 
error.
On
Off
There is a dc power problem.  
Possible causes:
1.
The server is not turned on (the power LED is blinking on 
the front of the server).  
Action: 
Press the power-control button to start the server.
2.
The power supply has failed.  
Action: 
Replace the power supply.
Off
Off
There is an ac power problem.  
Possible causes: 
1.
There is no ac power to the power supply.  
Actions: 
Verify that:  
The electrical cord is properly connected to 
the server.
The electrical outlet functions properly.
2.
The power supply has failed.  
Action: 
Replace the power supply.