Intel cpb4612 사용자 설명서

다운로드
페이지 104
 
 21
Default Jumper Configuration 
 
3.1 Switch 
Descriptions 
The following topics list the switches in numerical order and provide a detailed description of each switch.  
3.1.1 PB1 
(Reset) 
PB1 is a push-button on the front of the cPB-4612. Pressing PB1 issues a hard reset. Reset is discussed 
in more detail in Chapter 4. 
3.1.2  J16-1 (BKT-GND to GND) 
Installing this jumper will short the bracket ground to digital ground.  This may positively or negatively 
affect EMI emissions, depending on the system.  Proper testing would need to be performed with the 
intended system to determine the best setting.  The default is for no jumper. 
J16-1  
Function 
 
Open 
Default 
Bracket ground is not connected to digital ground. 
Closed 
 
Bracket ground is shorted to digital ground.