5-15
iECM-86 COMMANDS
5
resume the display by pressing the space bar a second time. You 
terminate the command by entering a carriage return.
5.4.6
STRING Commands
There is only one form of the STRING command:
STRING byte_address 
The line starts with a hexadecimal display of byte_address followed by the NUL-terminated
ASCII string starting at that address. For long strings, only the first 60 characters are dis-
played. When trailing characters are stripped, decimal points (.) are substituted for the first
three characters stripped. 
5.4.7
PORT Commands
There are four forms for the PORT command:
PORT 
port_address 
PORT 
port_address = byte_value 
 PORT 
port_address TO port_address 
 PORT 
port_address TO port_address = byte_value 
All of these commands can be used whether or not the user’s program is running.
PORT port_address 
This form is used to examine and then possibly change one or more 
sequential PORT variables. When this command is invoked, iECM-
86 displays the port_address in hexadecimal notation and the value 
of the PORT in the default base, then waits for an input from you. 
You can respond with a carriage return, an ESC, or a numeric value. 
A carriage return terminates the command. An ESC results in the 
display of the next sequential PORT variable. If a numeric value is 
entered, the PORT variable is set to this value and the iECM-86 
again waits for input. At this point, you can respond only with an 
ESC or carriage return. As before, the ESC displays the next 
sequential PORT and the carriage return terminates the command.
PORT port_address byte_value 
This form is used to set an individual PORT variable without first 
checking its current value. When invoked, this command sets the 
PORT variable at port_address to byte_value.
PORT port_address TO port_address 
This form is used to display a series of PORT variables. When this 
command is invoked, iECM-86 starts by displaying the current