Configuring ATM OC-3 Card Redundancy
3-9
Save the settings as follows:
CB5000>
 
save all
Repeat steps 1 and 2 for each LEC you require.
Assign a unique LES address for each bridgeport LEC on the same 
module. If a bridgeport LEC has an address configured that is a 
duplicate of another bridgeport LEC, it never joins the ELAN.
For a complete list of optional DMM LAN Emulation commands and 
parameters, see the
 ATM Backbone SwitchModule Command 
Reference. For descriptions and examples of the LAN Emulation 
commands, refer to the 
DMM Commands Guide.
Verifying
Bridgeport-LEC
Status
After Automatic or Manual LEC configuration, use the SHOW 
BPORT_LEC STATUS command to verify that the bridgeport-LEC is 
successfully joined to the intended ELAN.
Configuring ATM 
OC-3 Card 
Redundancy
If you install a second ATM OC-3 card on your ATM Backbone 
SwitchModule, use the following procedure to configure the module 
for ATM OC-3 card redundancy:
Use the following command to designate one of the two ATM OC-3 
cards as the active ATM OC-3 card.
CB5000> set module <slot>.1 phy_selection <1 or 2>
The ATM OC-3 card near the top of the ATM Backbone SwitchModule 
is 1. The lower ATM OC-3 card is 2.
The ATM OC-3 card you do not make active becomes the redundant 
ATM OC-3 card.
Use the following command to enable the ATM Backbone 
SwitchModule to automatically make the redundant ATM OC-3 card 
active if the primary ATM OC-3 card fails (or performance degrades 
significantly):
CB5000> set module <slot>.1 phy_automatic_failover enable