Operational Specifications 
3.2.2 External Power Supply Select Jumpers (JP2, JP3, and JP4) 
Rev.1.00 Oct 09, 2008 
3-18
REJ11J0021-0100  
 
 
 
3.2.2  External Power Supply Select Jumpers (JP2, JP3, and JP4) 
 
Set JP2 to JP4 to switch the power voltage source to the SH7137 system power (CPU-VCC), the analog power supply (AVCC), 
and the A/D reference power supply (AVREF). 
jumper setting. 
 
 
 
 
Figure 3.2.3 External Power Supply Select Jumper Assignments (JP2,JP3,JP4) 
 
Table 3.2.2 External Power Supply Select Jumper Setting (JP2,JP3,JP4) 
No. Setting 
Function 
1-2 
SH7137 power supply voltage (CPU-VCC) is supplied from J4 or J7 
JP2 
 CPU-VCC SEL 
Open 
External power supply voltage (supplied from J5 or H9) 
Do not leave the jumper open not supplying the power from an external source.
1-2 
SH7137 AVREF is connected to 5 V fixed power supply voltage 
JP3 
 AVREFSEL 
Open 
External power supply voltage (supplied from J8 or H10) 
1-2 
SH7137 AVCC is connected to the 5 V fixed power supply voltage   
JP4 
 AVCCSEL 
Open 
External power supply voltage (supplied from J8 or H11) 
     indicates the default setting. 
Note: Do not make any change with the jumper setting while the M3A-HS37 is operating. Ensure to turn the power OFF 
before changing the setting.