4.  PBX Systems 
buffer (shown below). The information for the top row (first 16 characters) of 
the display is checked. Data in bytes 00 through 15 indicate that Transfer is 
assigned to Memory Button 03.  
 
 
data 
54 72 61 6E 73 66 65 72
 
20 20 20 20 20 20 20 20
 
byte 
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
 
 
 
data 
20 20 20 20
 
20 20 20 20 20 20 20 20 20 20 20 20
 
byte 
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 
 
 
data 
xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx
 
byte 
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
 
 
 
Called/Calling Number ID (within the PBX) 
If receiving a call on a Dialogic
®
 PBX Integration Board from another 
extension, the PBX sends calling number ID data (by default, the extension 
number of the telephone placing the call) to the station set between the first 
and second rings. The station set processes the data and sends an ID message 
to the display. The calling number ID data sent from the PBX to the station set 
differs from the calling number ID data presented on the display.  
If placing a call to another extension, the called number ID (by default, the 
extension of the telephone being called) is shown in the display.  
Both the calling and called number IDs can be retrieved using one of the 
following: 
•  d42_gtcallid( ) function to retrieve the called/calling pair 
•  d42_gtcallidex( ) function to retrieve the called/calling ID, call type and 
reason code 
The d42_gtcallid( ) and d42_gtcallidex( ) functions retrieve the called/calling 
number ID message sent from the PBX to the station set, not the data sent to 
the display. Refer to the Dialogic
®
 PBX Integration Software Reference for 
more information about using the d42_gtcallid( ) and d42_gtcallidex( ) 
functions. 
127