Thermal Requirements
Hardware Preparation and Installation
MVME7100 Single Board Computer Installation and Use (6806800E08A)
33
 
2.3.3
Thermal Requirements
The MVME7100 module requires a minimum air flow of 10 CFM uniformly distributed across 
the board, with the airflow traveling from the heat sink to the PMC2 site, when operating at a 
55°C (131°F) ambient temperature.
2.3.4
Thermally Significant Components
The following table summarizes components that exhibit significant temperature rises. These 
are the components that should be monitored in order to assess thermal performance. The 
table also supplies the component reference designator and the maximum allowable operating 
temperature.
You can find components on the board by their reference designators as shown in 
Figure 2-1
 
and 
Figure 2-2
 on the next page. Versions of the board that are not fully populated may not 
contain some of these components.
The preferred measurement location for a component may be junction, case, or ambient as 
specified in the table. Junction temperature refers to the temperature measured by an on-chip 
thermal device. Case temperature refers to the temperature at the top, center surface of the 
component. Air temperature refers to the ambient temperature near the component.
Table 2-4 Thermally Significant Components
Reference 
Designator
Generic  Description
Maximum Allowable 
Component Temperature 
in Centigrade
Measurement Location
U27, U4
Gb Ethernet Transceiver
0
°
 to +70
°
Ambient
U25, U26, U28
PCI-X/PCI-Express 
Bridge
-40
°
 to +85
°
Ambient
U22
PCI-Express Bridge
-40
°
 to +85
°
Ambient
U24
VME Bridge
0
°
 to + 70
°
Ambient
U10, U11, U12, 
U13, U14, U56, 
U57, U58, U59, 
U6, U60, U61, 
U62, U63, U64, 
U7, U8, U9
DDR2 SDRAM
0
°
 to +95
°
Case
U20
MPU
0
°
 to +105
°
Junction