Toshiba MA-1650-4 사용자 설명서

다운로드
페이지 228
6. PROGRAMMING OPERATIONS
EO1-11110
6-31
ex.) To set the following Link-PLU Table and its Sub-link PLU:
Link-PLU Table No.
Sub-link PLU Code
1
101301
Mode Lock:  SET, 25 [@/FOR]
[ST]  101301 [PLU]  [AT/TL]
6.16  TARE TABLE AND GENERAL UNIT WEIGHT SETTING (Submode 26)
  TEC STORE
    1343 PEACH DRIVE
     PHONE : 87-6437
Open  8:00am to 7:00pm
Closed: every Wednesday
12-19-1994  MON #3001
    P25
#01 101301
            0055
NOTE:
In this example, Link-PLU Table No. has
already been set in PLU 90601 (Coke Small-B)
and PLU 90701 (7-up Small-B) as Head-link
items in the PLU PROGRAMMING operation,
Submode 4, The Sub-link PLU 101301 here
has been programmed as a bottle-deposit PLU
(Small-Btl Depo) in the same submode.
Repeatable for other tables to be deleted.
Deletion of Link-PLU Tables
CONDITION
Any time outside a sale
OPERATION
Mode Lock:  SET
25 [@/FOR]
[ITEM CORR]
|Link-PLU Table No.|  [ST]
[AT/TL]
or
[VOID]
In the PLU TABLE PROGRAMMING operation (Submode 4), some of Scale-compulsory PLUs may be set with a
Tare Table No.  The actual tare weight is set to each Tare Table here. Also, the General Unit Weight is set here
so that the Unit Weight may be effective to scale items entered through departments or PLUs without any
Individual Unit Weight designation.
CONDITION
Any time outside a sale
OPERATION
Mode Lock:  SET
26  [@/FOR]
|Tare Table No.|  [ST]
|Tare Weight|  [#]
0 to 999
(Unit:  1/100 LB or 1 gram.
Example:  enter 13 for 0.13 LB.)
*
Repeat for other tables.
* (For sequentially programming tables, the
Table No. specification can be skipped.)
1 to 9
|General Unit Weight Code|
[AT/TL]
Only to set
the General
Unit Weight
**
1 to 11
LB unit
Kg unit
1:
1 LB
1 Kg
9:
9 LB
9 Kg
10:
1/2 LB
100g
11:
1/4 LB
Not applicable
** Only to set the
Tare Weight
...
...
...