CDM-600 Satellite Modem 
Revision 7 
Remote Control  
MN/CDM600.IOM 
16–3 
 
16.5   
Packet Structure  
Controller-to-target: 
 
Start of Packet 
Target Address  Address  
De-limiter 
Instruction 
Code 
Code 
Qualifier 
Optional 
Arguments 
End of Packet 

ASCII code 60  
 
(1 character) 
 
 
 
(4 characters) 

ASCII code 47 
 
(1 character) 
 
 
 
(3 characters) 
= or ?  
ASCII code 
61 or 63 
(1 character) 
 
 
 
(n characters) 
Carriage 
Return 
ASCII code 13 
 
(1 character) 
 
Example: <0135/TFT=1[CR] 
 
Target-to-controller: 
 
Start of Packet 
Target 
Address 
Address  
De-limiter 
Instruction 
Code 
Code Qualifier 
Optional 
Arguments 
End of Packet 

ASCII  
code 62  
(1 character) 
 
 
 
(4 characters) 

ASCII  
code 47 
(1 character) 
 
 
 
(3 characters) 
=, ?, !, or *  
ASCII code 61, 
63, 33 or 42 
(1 character) 
 
 
(From 0 to n 
characters) 
Carriage Return, 
Line Feed 
ASCII code 13,10 
(2 characters) 
 
Example: >0654/RSW=32[CR][LF] 
 
Each of the components of the packet is now explained. 
 
16.5.1 
Start Of Packet 
Controller to Target: This is the character ‘<’ (ASCII code 60) 
  
Target to Controller: This is the character ‘>’ (ASCII code 62) 
Because this is used to provide a reliable indication of the start of packet, these two 
characters may not appear anywhere else within the body of the message. 
 
16.5.2 Address 
Up to 9,999 devices can be uniquely addressed. In EIA-232 applications this value is set 
to 0. In EIA-485 applications, the permissible range of values is 1 to 9999. It is 
programmed into a target unit using the front panel keypad. 
 
Important note: The controller sends a packet with the address of a target - the destination 
of the packet. When the target responds, the address used is the same address, to indicate 
to the controller the source of the packet. The controller does not have its own address.