Premier Mounts CDM-600 사용자 설명서

다운로드
페이지 250
CDM-600 Satellite Modem 
Revision 7 
ODU Operation 
MN/CDM600.IOM 
D–9 
D.2.13 
(ODU,ENABLE,1:1,CSAT#1) 
   MONITOR 
 
(ODU,ENABLE,1:1,CSAT#2) 
   MONITOR 
 
(ODU,ENABLE,STANDALONE 
CSAT) 
  MONITOR 
 MONITOR:  TRANSMIT RECEIVE MISCELLANEOUS 
   POWER-SUPPLIES
 
 
Use the [
←] or [→] keys to select the parameters to monitor, then press ENTER. 
D.2.14 (ODU,ENABLE,1:1,CSAT#1, 
MONITOR) 
 
TX 
 (ODU,ENABLE,1:1,CSAT#2, 
MONITOR) 
 
TX 
 
(ODU,ENABLE,STANDALONE CSAT, MONITOR)  TX 
 TX: SYNTUNE = 09.6 VDC  POWER = <24 dBm 
        IFLO = 11.1 VDC   TEMP = 26 C
 
 
Press ENTER or CLEAR to return to previous menu. 
D.2.15 (ODU,ENABLE,1:1,CSAT#1, 
MONITOR) 
 
RX 
 (ODU,ENABLE,1:1,CSAT#2, 
MONITOR) 
 
RX 
 
(ODU,ENABLE,STANDALONE CSAT, MONITOR)  RX 
 RX: SYNTUNE = 01.4 VDC   
        IFLO = 11.2 VDC   TEMP = 26 C
 
 
Press ENTER or CLEAR to return to previous menu. 
D.2.16 (ODU,ENABLE,1:1,CSAT#1, 
MONITOR) 
 
MISC 
 (ODU,ENABLE,1:1,CSAT#2, 
MONITOR) 
 
MISC 
 
(ODU,ENABLE,STANDALONE CSAT, MONITOR)  MISC 
 MISC: REF TUNE = 03.0 VDC 
       LNA = 00.05 mA   FAN = 550 mA
 
 
Press ENTER or CLEAR to return to previous menu.