CDM-600 Satellite Modem 
Revision 7 
ODU Operation 
MN/CDM600.IOM 
D–14 
D.2.29 
(ODU,ENABLE,STANDALONE 
KST,CONFIG)   TX 
 TX:OFF    FREQ=13955 MHz    ATT=23 dB 
                             AGC=OFF
 
 
Use the [
←] or [→] keys to select the parameter to edit. Use the [↑] or [↓] keys to edit 
the parameter, then press ENTER to implement, or CLEAR. 
 
The user may edit the TX Frequency, the TX Attenuation, the Amplifier setting or the 
AGC setting. 
D.2.30 (ODU,ENABLE,STANDALONE 
KST,CONFIG)   RX 
 RX: FREQ=11950 MHz   ATT=20 dB   REF=087 
     BAND=B
 
 
Note: The RX Band is not shown for the KST-2000A. 
 
Use the [
←] or [→] keys to select the parameter to edit. Use the [↑] or [↓] keys to edit 
the parameter, then press ENTER to implement, or CLEAR. 
 
The user may edit the RX Frequency, the RX Attenuation, the Ref setting or the RX Band 
(KST-2000B only). 
 
D.2.31 
(ODU,ENABLE,STANDALONE 
KST,CONFIG)   MISC 
 HPA:OFF    FAULT-LOGIC=SUMMARY 
L NA:OFF    FAULT-LOGIC=SUMMARY   CAL:NO
 
 
Use the [
←] or [→] keys to select the parameter to edit. Use the [↑] or [↓] keys to edit 
the parameter, then press ENTER to implement, or CLEAR. 
 
HPA state 
either OFF or ON - HPA power enable 
FAULT-LOGIC 
either SUMMARY or NO_SUMMary. This controls whether or not a HPA fault 
will be indicated on the Fault status and will activate the Summary Fault 
Relay. 
LNA state 
either OFF or ON - LNA power enable. 
FAULT-LOGIC 
either SUMMARY or NO_SUMMary. This controls whether or not a LNA fault 
will be indicated on the Fault status and will activate the Summary Fault 
Relay. 
CAL 
To calibrate, select YES and press ENTER. Calibration allows the system to 
determine nominal LNB or LNB power consumption, performed at initial 
installation only. (Default is NO.)