Troubleshooting
102
N300 Wireless ADSL2+ Modem Router DGN2200v3 
If the Power LED turns red to indicate a modem router fault, turn the power off and on to see 
if the modem router recovers. If the power LED is still red 1 minute after power-up:
•     
Turn the power off and on one more time to see if the modem router recovers.
•     
Clear the modem router’s configuration to factory defaults as explained in 
on page 109. This sets the modem router’s IP address to 192.168.0.1. 
If the error persists, you could have a hardware problem and should contact NETGEAR 
Technical Support.
LAN LED Is Off
If the appropriate LAN LED does not light when the Ethernet connection is made, check the 
following:
•     
The Ethernet cable connections are secure at the modem router and at the hub or 
workstation.
•     
The power is turned on to the connected hub or workstation.
•     
You are using the correct cable.
Cannot Log In to the Wireless-N Modem Router
If you are unable to log in to the modem router from a computer on your local network, check 
the following:
•     
If you are using an Ethernet-connected computer, check the Ethernet connection 
between the computer and the modem router as described in the previous section.
•     
Make sure that your computer’s IP address is on the same subnet as the modem router. 
If you are using the recommended addressing scheme, your computer’s address should 
be in the range of 192.168.0.2 to 192.168.0.254. 
•     
If your computer’s IP address is shown as 169.254.x.x, recent versions of Windows and 
MacOS will generate and assign an IP address if the computer cannot reach a DHCP 
server. These auto-generated addresses are in the range of 169.254.x.x. If your IP 
address is in this range, check the connection from the computer to the modem router, 
and reboot your computer.
•     
If your modem router’s IP address was changed and you do not know the current IP 
address, clear the modem router’s configuration to factory defaults. This sets the modem 
router’s IP address to 192.168.0.1. This procedure is explained in 
•     
Make sure that your browser has Java, JavaScript, or ActiveX enabled. If you are using 
Internet Explorer, click Refresh to be sure that the Java applet is loaded.
•     
Try quitting the browser and launching it again.
•     
Make sure you are using the correct login information. The factory default login name is 
admin
, and the password is password. Make sure that Caps Lock is off when you enter 
this information.