Acer 710 사용자 설명서

다운로드
페이지 98
1-16
EXTENSA 700/710 Service Guide
DC-AC inverter is used to generate very high AC voltage, then support to 
LCD CCFT backlight user, and is also responsible for the control of LCD 
brightness. Avoid touching the DC-AC inverter area while the system unit is 
turned on.
OVP (Over Voltage 
Protection, V)
5.52~5
.55
3.642~
3.693
15~17
7~9
-
OCP (Over Current 
Protection, A)
4~6
4~6
0.3~0.
4
-
-
DC-AC Inverter
Item
Specification
Vendor & model 
name
Ambit T622.087.C.00
Input voltage (V)
7.3 (min)
-
22 (max)
Input current 
(mA)
-
-
700 (max)
Output voltage 
(Vrms, no load)
1300 (min)
155
1600 (max)
Output voltage 
frequency (kHz)
40 (min)
-
65 (max)
Output current 
(mArms)
(T62.087.C.00)
0.7~5.9 (min)
1.0~6.5 (typ)
1.3~7.1 (max)
Output current 
(mArms)
(T62.086.C.00)
0.6~5.4 (min)
1.0~6.0 (typ)
1.4~6.6 (max)
LCD
Item
Specification
Vendor & model name
Hitachi 
SX31S002
IBM ITSV50D2
Hitachi 
TX34D62
Mechanical Specifications
LCD display area 
(diagonal, inch)
12.1
12.1
13.3
Display technology
STN
TFT
TFT
Resolution
SVGA 
(800x600)
SVGA 
(800x600)
XGA 
(1024x768)
Support colors
-
262,144 colors
DC-DC Converter
Item
Specification
700SG-1.fm  Page 16  Monday, June 8, 1998  6:38 PM