IBM 8185 사용자 설명서

다운로드
페이지 290
Power
 
Supply
 
Errors
 
If
 
the
 
power-on
 
indicator
 
is
 
not
 
on,
 
the
 
power
 
supply
 
fan
 
is
 
not
 
running,
 
or
 
the
 
computer
 
will
 
not
 
power-off,
 
use
 
the
 
following
 
procedures.
 
 
Check/Verify
 
FRU/Action
 
Check
 
the
 
following
 
for
 
proper
 
installation.
 
v
   
Power
 
Cord
 
v
   
On/Off
 
Switch
 
assembly
 
v
   
Power/LED
 
connector
 
v
   
System
 
Board
 
Power
 
Supply
 
connectors
 
v
   
Microprocessor(s)
 
Reseat
 
connectors
 
(see
 
Check
 
the
 
power
 
cord
 
for
 
continuity.
 
Power
 
Cord
 
Check
 
the
 
power
 
supply
 
voltages
 
See
 
  
Diagnostic
 
error
 
codes
 
Refer
 
to
 
the
 
following
 
diagnostic
 
error
 
codes
 
when
 
using
 
the
 
diagnostic
 
tests.
 
See
 
for
 
information
 
about
 
the
 
Diagnostic
 
programs.
 
In
 
the
 
following
 
index,
 
X
 
can
 
represent
 
any
 
number.
 
 
Diagnostic
 
Error
 
Code
 
FRU/Action
 
000-000-XXX
 
BIOS
 
Test
 
Passed
 
1.
   
No
 
action
 
000-002-XXX
 
BIOS
 
Timeout
 
1.
   
Flash
 
the
 
system
 
2.
   
System
 
board
 
000-024-XXX
 
BIOS
 
Addressing
 
test
 
failure
 
1.
   
Flash
 
the
 
system
 
2.
   
System
 
board
 
000-025-XXX
 
BIOS
 
Checksum
 
Value
 
error
 
1.
   
Flash
 
the
 
system
 
2.
   
Boot
 
block
 
3.
   
System
 
board
 
000-026-XXX
 
FLASH
 
data
 
error
 
1.
   
Flash
 
the
 
system
 
2.
   
Boot
 
block
 
3.
   
System
 
board
 
000-027-XXX
 
BIOS
 
Configuration/Setup
 
error
 
1.
   
Run
 
Setup
 
2.
   
Flash
 
the
 
system
 
3.
   
Boot
 
block
 
4.
   
System
 
board
 
000-034-XXX
 
BIOS
 
Buffer
 
Allocation
 
failure
 
1.
   
Reboot
 
the
 
system
 
2.
   
Flash
 
the
 
system
 
3.
   
Run
 
memory
 
test
 
4.
   
System
 
board
 
 
70
 
Hardware
 
Maintenance
 
Manual