Psion Teklogix 7530 G2 사용자 설명서

다운로드
페이지 296
Psion Teklogix 7530 G2 Hand-Held Computer User Manual
217
Chapter 6: Peripheral Devices & Accessories
Operator Controls
A green indicator in the lower-right lights to indicate power is present. All charge 
indicators flash momentarily at powerup to indicate that the charger is ready for 
operation.
If you choose to wall mount the charger, follow the instructions packaged with the 
mounting bracket kit. Be sure to locate the charger in an area where there is no risk 
of injury to persons walking in the vicinity.
6.5.2  Operator Controls
The gang charger does not have operator controls or a power switch. 
6.5.3  Charge Indicators
Each battery charge slot is equipped with a tri-coloured LED to indicate the charge 
status of the battery. When 7530 G2 batteries are inserted in the charger, the colour 
and behaviour of the LEDs associated with the charge wells in use indicate the 
status of the charge.
Table 6.1  Gang Charger Indicators
6.5.4  Charging Batteries
Install the battery with the battery contacts facing the charger. Slide the 
battery between the guide rails until it lightly latches in place. 
LED Behaviour
Icon
Charge Status
Off
No battery detected in the slot.
Solid green
Battery is fully charged. 
Flashing green
Battery is charged to 75% capacity.
Solid yellow
Charge in progress.
Flashing 
yellow
Battery temperature out of charge range between 5° C 
to 39° C (41° F to 102° F). This icon indicates that the 
charger is waiting to charge. Charging is attempted 
every five minutes until the battery is within the 
appropriate temperature range.
Solid red
Battery rejected (at insertion) or unable to complete 
charge on battery
Flashing red
Charging circuit problem. Refer to “Troubleshooting” 
on page 218.