Upgrading the system
Issue 3.0 February 2002
65
Troubleshooting upgrade failures
If you receive an error message that one of the installation scripts failed when you run the 
cvue_activate
 command, you may be able to recover and continue with the upgrade. 
Some of the installation scripts can be skipped during this part of the upgrade. However, 
any script that is skipped during this part of the upgrade must be installed later using the 
standard software installation procedures found in the CMS software installation 
document.
The following table lists all of the possible software installation scripts, and explains what to 
do if one of them fails during the upgrade. When identifying the installation scripts, be 
aware that each script is numbered with a prefix (for example, S04) before the script name.
Script name
Description
How to recover
install_sql
ISQL software
All of these scripts install optional software or 
drivers needed by the customer. You can skip the 
script and reinstall the software later. To skip the 
script:
1. Enter: 
cd /adminsave/init.d
2. Enter: 
mv 
scriptname /adminsave/
 where 
scriptname
 is the name of the script.
3. Enter: 
cd /cdrom/cdrom0
4. Run the 
./cvue_activate
 command again.
5. Install the software package that you skipped 
before you migrate the customer’s data.
After each script is executed, a copy of the script is 
moved to /adminsave/init.d.completed.
x25_setup
Set up X.25
install_nts
NTS drivers
install_hsip
HSI/P drivers
install_hsis
HSI/S drivers
install_saip
SAI/P drivers
install_saipu
SAI/P utilities
install_tokenring_s
Token Ring software
install_tokenring_p
Token Ring software
install_odbcX_X
ODBC software