American Dryer Corp. Phase 7.2.2 사용자 설명서
78
SECTION IX
PHASE 7 NON-COIN AUTO CYCLE (PATENT NO. 4,827,627)
CYCLE ADJUSTMENT VALUES
IMPORTANT: If your particular model/dryer dryness levels are not shown in the above charts,
contact the Service Department for the appropriate factors for your particular dryer.
When doing so, please have the dryer model and serial numbers available.
When doing so, please have the dryer model and serial numbers available.
IMPORTANT: The adjustment values have been preprogrammed by the factory, but can be changed
in the field. IF THE PHASE 7 NON-COIN MICROPROCESSOR
CONTROLLER (COMPUTER) SHOULD FAIL AND IS BEING
REPLACED, THE REPLACEMENT PHASE 7 NON-COIN
MICROPROCESSOR CONTROLLER (COMPUTER) MUST BE
REPROGRAMMED FOR THE SPECIFIC MODEL SHOWN IN THE
ADJUSTMENT VALUE PARAMETERS CHARTS ABOVE. THE
ADJUSTMENT VALUE LABEL IS LOCATED ON THE TOP CONTROL
PANEL, BEHIND THE KEYBOARD (TOUCH PAD) DISPLAY DOOR.
CONTROLLER (COMPUTER) SHOULD FAIL AND IS BEING
REPLACED, THE REPLACEMENT PHASE 7 NON-COIN
MICROPROCESSOR CONTROLLER (COMPUTER) MUST BE
REPROGRAMMED FOR THE SPECIFIC MODEL SHOWN IN THE
ADJUSTMENT VALUE PARAMETERS CHARTS ABOVE. THE
ADJUSTMENT VALUE LABEL IS LOCATED ON THE TOP CONTROL
PANEL, BEHIND THE KEYBOARD (TOUCH PAD) DISPLAY DOOR.
NOTE: When fine-tuning the Auto Cycle for certain loads, if the clothes comes out wet decrease the
adjustment value; if the material comes out too dry, increase the adjustment value.
Gas
Model
Adjustment
Value
MLG-55
65
MLG-758
60
MLG-75V
70
MLG-78
70
MLG-82
62
MLG-96
70
MLG-122
70
MLG-130
73
MLG-170
68
Electric
Model
Adjustment
Value
MLE-120ES
78
MLE-170SE
70
Steam
Model
Adjustment
Value
MLS-130
65
MLS-170
70