Cisco Systems NPE-225 사용자 설명서
7-27
Network Processing Engine and Network Services Engine Installation and Configuration
OL-4448-12
Chapter 7 NPE-G1 and NPE-G2 Installation and Configuration Information
Installing the NPE-G1 or NPE-G2
Figure 7-15
Removing or Installing an SDRAM SODIMM
Step 3
Remove the SODIMM from the socket. Avoid touching the SODIMM as much as possible, particularly
the traces, the metal fingers on the connector side of the SODIMM.
the traces, the metal fingers on the connector side of the SODIMM.
Step 4
Place the SODIMM in an antistatic shielding bag.
Installing a SDRAM SODIMM
Caution
SODIMMs are sensitive components that are susceptible to ESD damage. Handle SODIMMs by the
edges only; avoid touching the memory modules, pins, or traces (the metal fingers along the connector
edge of the SODIMM).
edges only; avoid touching the memory modules, pins, or traces (the metal fingers along the connector
edge of the SODIMM).
Step 1
Remove a new SODIMM from the antistatic container.
Step 2
Hold the SODIMM component-side-up, with the connector edge (the metal fingers) away from you.
Step 3
Align the new SODIMM notch with the connector and insert the SODIMM into the socket.
Caution
When inserting the SODIMM, use firm but not excessive pressure. If you damage a socket, you will have
to return the NPE-G1 to the factory for repair.
to return the NPE-G1 to the factory for repair.
Step 4
Gently press on the SODIMM until the SODIMM spring latches snap into place.
1
SODIMM
66437
1