Step 1
Connect one end of the RJ-45 crossover cable to the RJ-45 port (labeled CONSOLE) on the supervisor.
Step 2
Connect the other end of the cable to the appropriate port on the PC or terminal to complete the console port cable 
connection. 
Management Port
The management port provides an Ethernet port to a LAN for a 10BASE-T and 100BASE-T connection for network 
management. 
Step 1
Connect one end of the RJ-45 Ethernet cable to the RJ-45 port (labelled Management on the supervisor card).
Step 2
Connect the other end of the cable to the appropriate port on the PC or console to complete the management port cable 
connection. 
Cabling the Cisco RFGW-10 UEQAM
The following tools are required for the Cisco RFGW-10 coaxial termination:
  •
12 universal cable holders UCH2 (supplied in the accessory kit)
  •
T-10 TORX driver tool 
  •
¼” flat head screwdriver
  •
MCX terminated cable bundle (optional)
Figure 14
Universal Cable Holder UCH2
155821
Shroud
Red line
Large pin
Screws into
faceplate
TORX screw
TORX screw
Cutout
Cutout
Small pin
Lead
screw
Lock bar