Cisco Systems 57712 사용자 설명서

다운로드
페이지 288
Procedure
Purpose
Command or Action
Enters the chassis command mode.
Server# scope chassis
Step 1
(Optional) Displays the available adapter devices.
Server /chassis # show adapter
Step 2
Enters the command mode for the adapter card at the PCI
slot number specified by index.
Server /chassis # scope adapter
index
Step 3
The server must be powered on before you can view
or change adapter settings.
Note
Enables or disables FCoE Initialization Protocol (FIP) on
the adapter card. FIP is enabled by default.
Server /chassis/adapter # set
fip-mode 
{disable enable}
Step 4
We recommend that you disable this option only
when explicitly directed to do so by a technical
support representative.
Note
Enables or disables Network Interface Virtualization (NIV)
on the adapter card. NIV is disabled by default.
Server /chassis/adapter # set
niv-mode 
{disable enable}
Step 5
If NIV mode is enabled, vNICs:
• Can be assigned to a specific channel
• Can be associated with a port profile
• Can fail over to another vNIC if there are
communication problems
If NIV mode is enabled, port-count specifies the number of
VM FEX interfaces you want CIMC to create, from 0 to 112.
Server /chassis/adapter #
configure-vmfex port-count
Step 6
Commits the transaction to the system configuration.
Server /chassis/adapter # commit
Step 7
This example configures the properties of adapter 1:
Server#
scope chassis
Server /chassis #
scope adapter 1
Server /chassis/adapter #
set fip-mode enable
Server /chassis/adapter *#
commit
Server /chassis/adapter #
Managing vHBAs
Guidelines for Managing vHBAs
When managing vHBAs, consider the following guidelines and restrictions:
• The Cisco UCS P81E Virtual Interface Card and Cisco UCS VIC1225 Virtual Interface Card provide
two vHBAs (fc0 and fc1). You can create up to 16 additional vHBAs on these adapter cards.
   Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
86
OL-28893-01  
Managing Network Adapters
Managing vHBAs