Cisco Systems 57712 사용자 설명서

다운로드
페이지 288
Server /chassis/adapter #
show host-eth-if eth0 detail
Name eth0:
MTU: 1500
Uplink Port: 0
MAC Address: 00:22:BD:D6:5C:33
CoS: 0
Trust Host CoS: disabled
PCI Order: ANY
VLAN: NONE
VLAN Mode: TRUNK
Rate Limiting: OFF
PXE Boot: enabled
Channel Number: N/A
Port Profile: N/A
Uplink Failover: N/A
Uplink Failback Timeout: N/A
Server /chassis/adapter #
Modifying vNIC Properties
Before You Begin
You must log in with admin privileges to perform this task.
Procedure
Purpose
Command or Action
Enters the chassis command mode.
Server# scope chassis
Step 1
(Optional) Displays the available adapter devices.
Server /chassis # show adapter
Step 2
Enters the command mode for the adapter card at the
PCI slot number specified by index.
Server /chassis # scope adapter index
Step 3
The server must be powered on before you can
view or change adapter settings.
Note
Enters the host Ethernet interface command mode for
the specified vNIC.
Server /chassis/adapter # scope
host-eth-if 
{eth0 eth1 name}
Step 4
Specifies the maximum transmission unit (MTU) or
packet size that the vNIC accepts. Valid MTU values
are 1500 to 9000 bytes; the default is 1500.
Server /chassis/adapter/host-eth-if # set
mtu 
mtu-value
Step 5
Specifies the uplink port associated with this vNIC. All
traffic for this vNIC goes through this uplink port.
Server /chassis/adapter/host-eth-if # set
uplink 
{1}
Step 6
Specifies a MAC address for the vNIC in the form
hh:hh:hh:hh:hh:hh or hhhh:hhhh:hhhh.
Server /chassis/adapter/host-eth-if # set
mac-addr 
mac-addr
Step 7
Specifies the class of service (CoS) value to be marked
on received packets unless the vNIC is configured to
Server /chassis/adapter/host-eth-if # set
cos 
cos-value
Step 8
trust host CoS. Valid CoS values are 0 to 6; the default
is 0. Higher values indicate more important traffic.
   Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
100
OL-28893-01  
Managing Network Adapters
Modifying vNIC Properties