Cisco Systems 57712 사용자 설명서

다운로드
페이지 288
System Event Log
Viewing the System Event Log
Procedure
Purpose
Command or Action
Enters the system event log (SEL) command mode.
Server# scope sel
Step 1
For system events, displays timestamp, the severity of the
event, and a description of the event. The detail keyword
Server /sel # show entries
[detail]
Step 2
displays the information in a list format instead of a table
format.
This example displays the system event log:
Server#
scope sel
Server /sel #
show entries
Time
Severity
Description
------------------- ------------- ----------------------------------------
[System Boot]
Informational " LED_PSU_STATUS: Platform sensor, OFF event was asserted"
[System Boot]
Informational " LED_HLTH_STATUS: Platform sensor, GREEN was asserted"
[System Boot]
Normal
" PSU_REDUNDANCY: PS Redundancy sensor, Fully Redundant
was asserted"
[System Boot]
Normal
" PSU2 PSU2_STATUS: Power Supply sensor for PSU2, Power
Supply input lost (AC/DC) was deasserted"
[System Boot]
Informational " LED_PSU_STATUS: Platform sensor, ON event was asserted"
[System Boot]
Informational " LED_HLTH_STATUS: Platform sensor, AMBER was asserted"
[System Boot]
Critical
" PSU_REDUNDANCY: PS Redundancy sensor, Redundancy Lost
was asserted"
[System Boot]
Critical
" PSU2 PSU2_STATUS: Power Supply sensor for PSU2, Power
Supply input lost (AC/DC) was asserted"
[System Boot]
Normal
" HDD_01_STATUS: Drive Slot sensor, Drive Presence was
asserted"
[System Boot]
Critical
" HDD_01_STATUS: Drive Slot sensor, Drive Presence was
deasserted"
[System Boot]
Informational " DDR3_P2_D1_INFO: Memory sensor, OFF event was asserted"
2001-01-01 08:30:16 Warning
" PSU2 PSU2_VOUT: Voltage sensor for PSU2, failure event
was deasserted"
2001-01-01 08:30:16 Critical
" PSU2 PSU2_VOUT: Voltage sensor for PSU2, non-recoverable
event was deasserted"
2001-01-01 08:30:15 Informational " LED_PSU_STATUS: Platform sensor, ON event was asserted"
2001-01-01 08:30:15 Informational " LED_HLTH_STATUS: Platform sensor, AMBER was asserted"
2001-01-01 08:30:15 Informational " LED_HLTH_STATUS: Platform sensor, FAST BLINK event was
asserted"
2001-01-01 08:30:14 Non-Recoverable " PSU2 PSU2_VOUT: Voltage sensor for PSU2, non-recoverable
event was asserted"
2001-01-01 08:30:14 Critical
" PSU2 PSU2_VOUT: Voltage sensor for PSU2, failure event
was asserted"
--More--
   Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
170
OL-28893-01  
Viewing Logs
System Event Log