Cisco Systems 57712 사용자 설명서

다운로드
페이지 288
• Cisco Flexible Flash must be supported on your server.
Procedure
Purpose
Command or Action
Enters the chassis command mode.
Server# scope chassis
Step 1
Enters the Cisco Flexible Flash controller command
mode for the specified controller. At this time, the
only permissible index value is FlexFlash-0.
Server /chassis # scope flexflash index
Step 2
Copies the configuration from the primary slot to the
secondary slot.
Server /chassis/flexflash # retain
config 
primary slot ID
Step 3
Commits the transaction to the system configuration.
Server /chassis/flexflash # commit
Step 4
This example shows how to copy the configuration from one slot to the other:
Server#
scope chassis
Server /chassis #
scope flexflash FlexFlash-0
Server /chassis/flexflash #
retain-config slot1
This action will copy the config of slot1 to both the slots, mark slot1 as healthy,
primary slot and slot2 (card must be present) as unhealthy secondary active.
This operation may disturb the host connectivity as well.
Continue? [y|N] y
Server /chassis/flexflash/operational-profile *#
commit
Server /chassis/flexflash/operational-profile #
Configuring BIOS Settings
Viewing BIOS Status
Procedure
Purpose
Command or Action
Enters the BIOS command mode.
Server# scope bios
Step 1
Displays details of the BIOS status.
Server /bios # show detail
Step 2
The BIOS status information contains the following fields:
Description
Name
The version string of the running BIOS.
BIOS Version
   Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5
30
OL-28893-01  
Managing the Server
Configuring BIOS Settings