This example displays temperature sensor statistics:
Server#
scope sensor
Server /sensor #
show temperature
Name
Sensor Status
Reading
Units
Min. Warning Max. Warning
Min. Failure Max. Failure
------------------------- -------------- ---------- ---------- ------------ ------------
------------ ------------
IOH_TEMP_SENS
Normal
32.0
C
N/A
80.0
N/A
85.0
P2_TEMP_SENS
Normal
31.0
C
N/A
80.0
N/A
81.0
P1_TEMP_SENS
Normal
34.0
C
N/A
80.0
N/A
81.0
DDR3_P2_D1_TMP
Normal
20.0
C
N/A
90.0
N/A
95.0
DDR3_P1_A1_TMP
Normal
21.0
C
N/A
90.0
N/A
95.0
FP_AMBIENT_TEMP
Normal
28.0
C
N/A
40.0
N/A
45.0
Server /sensor #
Viewing Voltage Sensors
Procedure
Purpose
Command or Action
Enters sensor command mode.
Server# scope sensor
Step 1
Displays voltage sensor statistics for the
server.
Server /sensor # show voltage [detail]
Step 2
This example displays voltage sensor statistics:
Server#
scope sensor
Server /sensor #
show voltage
Name
Sensor Status
Reading
Units
Min. Warning Max. Warning
Min. Failure Max. Failure
------------------------- -------------- ---------- ---------- ------------ ------------
------------ ------------
P3V_BAT_SCALED
Normal
3.022
V
N/A
N/A
2.798
3.088
P12V_SCALED
Normal
12.154
V
N/A
N/A
11.623
12.331
P5V_SCALED
Normal
5.036
V
N/A
N/A
4.844
5.157
P3V3_SCALED
Normal
3.318
V
N/A
N/A
3.191
3.381
P5V_STBY_SCALED
Normal
5.109
V
N/A
N/A
4.844
5.157
PV_VCCP_CPU1
Normal
0.950
V
N/A
N/A
0.725
1.391
PV_VCCP_CPU2
Normal
0.891
V
N/A
N/A
0.725
1.391
P1V5_DDR3_CPU1
Normal
1.499
V
N/A
N/A
1.450
1.548
P1V5_DDR3_CPU2
Normal
1.499
V
N/A
N/A
1.450
1.548
P1V1_IOH
Normal
1.087
V
N/A
N/A
1.068
1.136
P1V8_AUX
Normal
1.773
V
N/A
N/A
Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.5    
   OL-28893-01
51
Viewing Server Sensors
Viewing Voltage Sensors