Table 5:  Input Terminal Status Monitor (parameter 000D) 
Bit Input 
Terminal 
Single-Bit 
Read Mask 
bit 0 
terminal - CC open 
terminal - CC shorted 
0001 
bit 1 
terminal - CC open 
terminal - CC shorted 
0002 
bit 2 
S1 
terminal - CC open 
terminal - CC shorted 
0004 
bit 3 
S2 
terminal - CC open 
terminal - CC shorted 
0008 
bit 4 
S3 
terminal - CC open 
terminal - CC shorted 
0010 
bit 5 
S4 
terminal - CC open 
terminal - CC shorted 
0020 
bit 6 
S5 (option) 
terminal - CC open 
terminal - CC shorted 
0040 
Lower 
Byte 
bit 7 
S6 (option) 
terminal - CC open 
terminal - CC shorted 
0080 
 
Bit Input 
Terminal 
Single-Bit 
Read Mask 
bit 0 
unused (always 0) 
 
 
 
bit 1 
unused (always 0) 
 
 
 
bit 2 
unused (always 0) 
 
 
 
bit 3 
unused (always 0) 
 
 
 
bit 4 
unused (always 0) 
 
 
 
bit 5 
S7 (option) 
terminal - CC open 
terminal - CC shorted 
0020 
bit 6 
RES 
terminal - CC open 
terminal - CC shorted 
0040 
Upper 
Byte 
bit 7 
ST 
terminal - CC open 
terminal - CC shorted 
0080 
 
Table 6:  Output Terminal Status Monitor / Inverter Status 2 (parameter 000E) 
Bit Output 
Terminal 
Single-Bit 
Read Mask 
bit 0 
unused (always 0) 
 
 
 
bit 1 
unused (always 0) 
 
 
 
bit 2 
FAN 
OFF 
ON 
0004 
bit 3 
FL 
FLB-FLC shorted FLA-FLC 
shorted  0008 
bit 4 
MS relay 
OFF 
ON 
0010 
bit 5 
OUT (option) 
OUTB-OUTC shorted 
OUTA-OUTC shorted 
0020 
bit 6 
RCH 
RCHA-RCHC open 
RCHA-RCHC shorted 
0040 
Lower 
Byte 
bit 7 
LOW 
LOWA-LOWC open 
LOWA-LOWC shorted 
0080 
 
Bit Inverter 
Status 
Single-Bit 
Read Mask 
bit 0 
accelerating 
not accelerating 
accelerating 
0001 
bit 1 
decelerating 
not decelerating 
decelerating 
0002 
bit 2 
for inverter use 
 
 
 
bit 3 
retry 
not retrying 
retrying 
0008 
bit 4 
running (including DC 
injection braking) 
stopped running 
0010 
bit 5 
for inverter use 
 
 
 
bit 6 
for inverter use 
 
 
 
Upper 
Byte 
bit 7 
tripped 
not tripped 
tripped 
0080