Panasonic WV-CU650 사용자 설명서

다운로드
페이지 78
18
2. Set the Line termination switch of other system con-
trollers to OFF.
● Setting for Terminal Mode
Set the MODE Switch #1 and #5 to ON.
Note: Refer to the following document for details on con-
nections and operations.
Addendum for WV-CU650 and WJ-SX150 Series
■ CONTROLLER NO. Switch
Setting
You will determine controller-number settings by moving
the CONTROLLER NO. switch at the rear panel.
If using only one system controller
Maintain the switch setting as “1 (factory default position)”.
If using two or more system controllers in
daisy chain connections
Up to 4 system controllers are connectable in the system. 
To avoid conflict, set the unique number for each system
controller.
Notes:
• “0” and “9” are reserved numbers. They cannot be set
for controller numbers.
• One of the system controllers must be set to "1".
System units
Line termination ON
Line termination OFF
Line termination OFF
Line termination OFF Line termination ON
CONTROLLER No.
0
9
8
7
6
5
4
3
2
1
SETUP PROCEDURES (HARDWARE)
■ Setup Procedures
Perform the setup as follows.
1. Set the MODE switches.
You will set up the communication mode and line termi-
nation ON/OFF of RS-485 communication. (Refer to
MODE Switch Setting.)
2. Set CONTROLLER NO. switches.
You will perform this setting when using two or more
system controllers in daisy chain connections. (Refer to
CONTROLLER NO. Setting.)
3. Perform WV-CU650 setups after entering the
administrator password.
You will perform the settings concerning password and
communication between system controllers and other
system units, etc. (Refer to p. 19.)
Note: Before performing WV-CU650 setups, you need to
log into the system by entering the administrator pass-
word. (Refer to p. 19.)
■ MODE Switch Setting
You will perform the setting of the MODE switches at the
rear panel.
Notes:
• Before the setting, turn off the system controller. (Refer
to p. 27 Power-off.)
• Do not move the MODE switches to positions other than
described in these illustrations. That may cause mal-
function.
● Setting for PS·Data Mode
If using only one system controller
Set the MODE Switch #5 to ON.
If using two or more system controllers in
daisy chain connections
1. Set the MODE Switch #5 of the system controller at the
chain end to ON.
1
2
3
4
5
6
7
8
OFF
ON
MODE Switch #5 (Line termination switch)
1
2
3
4
5
6
7
8
OFF
ON
1
2
3
4
5
6
7
8
OFF
ON