Setting/releasing the limiters
O
For the controller AW-RP301/AW-RP305/AW-RP501/AW-RP505
1. To set the upper limit position of the
travel range:
Using the controller, tilt the camera to
the position which is to serve as the
upper limit.
While holding down the MEMORY button
on the controller, press PRESET button
2 and PRESET button 3 simultaneously
for at least 5 seconds.
The setting is completed as soon as the
lamp of the PRESET button 5 comes on.
To release the setting:
While holding down the MEMORY button
on the controller, press PRESET button
2 and PRESET button 3 simultaneously
for at least 5 seconds.
The setting is released when the lamp of
the PRESET button 10 comes on.
2. To set the lower limit position of the
travel range:
Using the controller, tilt the camera to
the position which is to serve as the
lower limit.
While holding down the MEMORY button
on the controller, press PRESET button
7 and PRESET button 8 simultaneously
for at least 5 seconds.
The setting is completed as soon as the
lamp of the PRESET button 5 comes on.
To release the setting:
While holding down the MEMORY button
on the controller, press PRESET button
7 and PRESET button 8 simultaneously
for at least 5 seconds.
The setting is released when the lamp of
the PRESET button 10 comes on.
3. To set the left-most limit position of
the travel range:
Using the controller, tilt the camera to
the position which is to serve as the left-
most limit.
While holding down the MEMORY button
on the controller, press PRESET button
1 and PRESET button 6 simultaneously
for at least 5 seconds.
The setting is completed as soon as the
lamp of the PRESET button 5 comes on.
To release the setting:
While holding down the MEMORY button
on the controller, press PRESET button
1 and PRESET button 6 simultaneously
for at least 5 seconds.
The setting is released when the lamp of
the PRESET button 10 comes on.
4. To set the right-most limit position of
the travel range:
Using the controller, tilt the camera to
the position which is to serve as the
right-most limit.
While holding down the MEMORY button
on the controller, press PRESET button
4 and PRESET button 9 simultaneously
for at least 5 seconds.
The setting is completed as soon as the
lamp of the PRESET button 5 comes on.
To release the setting:
While holding down the MEMORY button
on the controller, press PRESET button
4 and PRESET button 9 simultaneously
for at least 5 seconds.
The setting is released when the lamp of
the PRESET button 10 comes on.