Toshiba H9 사용자 설명서

다운로드
페이지 289
44
H9 ASD Installation and Operation Manual
Torque
  Displays the Output Torque as a percentage of the rated capacity of the H9 ASD.
Torque Reference
  Displays the Torque Reference as a percentage.
Torque Current
  Displays the torque-producing current value.
Excitation Current
  Displays the current value required to produce the excitation field.
PID Feedback
 — Provides a status of the PID Real Time Feedback in Hz.
Input Power
 — Displays the Input Power in Kilowatts (Kw).
Output Power
 — Displays the Output Power in Kilowatts (Kw).
Pattern Group Number
 — Displays the active Pattern Run Group Number.
Pattern Group Cycle
 — Displays the cycle number of the active Pattern Run Group.
Pattern Group Preset
 — Displays the active Preset Speed being run of the active Pattern Run 
Group.
Pattern Time
 — Displays the remaining time for the active Pattern Run Group.
RR
 — Displays the RR input value as a percentage of the full range of the RR value (potentiometer 
input).
*
V/I
 — Displays the V/I input setting as a percentage of the full range of the V/I value.
Note:
The isolated V/I input terminal may receive Current or Voltage to control the 
output speed or the output torque. The input signal type must be selected at SW301 
on the Terminal Board
 
 
The input setting of SW301 is used for the 0 – 10 VDC analog input signal and 
the input setting of SW301 is used for the 0 – 20 mA analog input signal. Either 
may be used as a frequency or torque command source. See parameter 
 for 
more information on the setup of this terminal. 
 
 
On the LCD display the V/I terminal is listed as the VI/II terminal (the additional 
letter I is used to indicate “input.”).
RX
 — Displays the RX input setting as a percentage of the full range of the RX value (-10 to
 
+10 VDC input).
RX2 Option (AI1)
 — Displays the RX2 input setting as a percentage of the full range of the RX2 
value.
Note:
The RX2 function is available on the Expansion IO Card Option 1 option board 
 
(P/N ETB003Z) only.
Trip Code
 — Displays None if there are no errors, or displays one of the associated Fault Codes 
listed in 
 if there is an active Fault (e.g., E = Emergency Off).
Past Trip #1
 — This function records and displays the last trip incurred. Subsequent trips will 
replace Past Trip #1. As trip records are replaced they are shifted to the next level of the Past Trip 
locations until being deleted (i.e., Past Trip #1 is moved to Past Trip #2 and then to #3 until being 
shifted out of #4). Once shifted out of Past Trip #4 the record is deleted. If no trips have occurred 
since the last reset, None is displayed for each trip record.
Past Trip #2
 — Past Trip information.
Past Trip #3
 — Past Trip information.
Past Trip #4
 — Past Trip information.
Note:
An improper H9 ASD setup may cause some trips — reset the H9 ASD to the 
Factory Default settings before pursuing a systemic malfunction (Program 
 
Utilities 