NEC NDA-30115-001 사용자 설명서
Page B-2
NDA-30115 Revision 1.0
PMS Line Failure Printouts
Property Management System - Communication Interface
Abnormal Events
When the NEAX receives a message from the PMS, and the received data is
abnormal or it cannot be processed by the NEAX, the message is printed out.
abnormal or it cannot be processed by the NEAX, the message is printed out.
Figure B-3 Abnormal Events Printout
Abnormal Port
If an external port of the NEAX is in an abnormal state, the abnormality will be
printed out.
printed out.
Figure B-4 Abnormal Port Printout
Table B-2 Wake Up Results
Wake Up Results
Explanation
ATT ANSWER
Attendant Console answers.
ATT CALLED
Attendant Console has been called.
ATT CALLING: ROOM STA ANSWER
While Attendant Console is calling, a
guest room station has answered.
guest room station has answered.
ATT NO ANSWER: ROOM STA CALLED
An Attendant Console has not
answered, a guest room station has
been called.
answered, a guest room station has
been called.
ROOM STA BUSY
A guest room station is currently on a
call.
call.
Entry Error
[XX-X] INPUT ERR XXXXXXXXXXXXXXXX... XX:XX
Message Data
Error Number:
Current Time
HP Task Error
[EXXX] HI=XX XX XX XX XX ... XX:XX
Current Time
Data to be processed
Task Error Number
FTC-FC of return violation code
[I/O PKG NOT READY] PORT NO = X STATUS = XX XX XX XX XX:XX
Failure Type
Port Number
Port State Current Time