NEC NDA-30115-001 사용자 설명서

다운로드
페이지 116
NDA-30115  Revision 1.0
Page 45
Property Management System - Communication Interface
Message Formats
Check Out 
Outgoing Call 
Report
Figure 4-15   Check Out Outgoing Call Report
The only message field is the extension number who is being checked out. If
the extension number is less than six digits, left justify the number and fill
the remaining bytes with space (20H) characters.
Check Out 
Message Waiting 
Report
Figure 4-16   Check Out
Message fields are:
Extension -- Extension number. If the extension number is less than six digits, 
left justify the number and fill the remaining bytes with space (20H) characters.
Status -- Message Waiting Lamp status. The status values are:
0 -- No messages waiting.
1 -- Message waiting set by the NEAX.
4 -- Message waiting set by the PMS.
5 -- Message waiting set by both the PMS and NEAX.
Blank -- Field contains one space (20H) character.
‘C’
‘1’ ‘6’
‘1’
‘1’
Extension
0
1
2
3
4
6
8
9
15
16
STX
SA
UA
EI
FTC
MSC
FC
6
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
‘1’ ‘6’
‘1’
‘3’
0
1
2
3
4
6
8
9
15
STX
SA
UA
EI
FTC
MSC
FC
6
1
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
1
16
17
18
Blank
‘D’ Extension
Status