DIP-SWITCH SETTINGS
Front Panel DIP-Switch Settings
Fig. 3   Front Panel DIP-Switches
Link Segment/Link Propagate “LS/LP” DIP-Switch
This DIP-Switch controls the Link Propagate or Link
Segment modes.  When the DIP-Switch is in the “LS”
position (factory setting), Link Segment mode is enabled.
In the “LP” position, Link Propagate mode is enabled.
Remote Fault Detection “RFD” DIP-Switch
To enable Remote Fault Detection mode, set the “RFD”
DIP-Switch to the “RFD” position.
To enable RFD + LS mode, also set the LS/LP DIP-
Switch to the “LS” position.  To enable RFD + LP mode,
set the LS/LP DIP-Switch to the “LP” position.
The RFD DIP-Switch selection is ignored on ports set to
Auto-Negotiation mode.
NOTE:  Connecting two converters with both set to RFD
mode is  not supported and will cause a “deadly embrace”
lockup.
Symmetrical Fault Detection “SFD” DIP-Switch
To enable Symmetrical Fault Detection mode, set the
“SFD” DIP-Switch to the “SFD” position, the “LS/LP”
DIP-Switch to the “LS” position and the “RFD”
DIP-Switch to the “Off” position.
Any other DIP-Switch configuration will disable
Symmetrical Fault Detection mode.
NOTE:   Converters in SFD mode must be deployed in pairs.
Board-Mounted DIP-Switches
 
BPAEN
BPBEN
MAN
=
=
=
Backplane “A” Enabled
Backplane “B” Enabled
P1 Manual
AN
=
Off
Off
P1 Auto Negotiate
ON
HD
= P2 Half Duplex
FD
=
P2 Full Duplex
1
2
3
4
5
6
7
8
Fig. 4   Board Mounted DIP-Switches
Backplane A Enable  “BPAEN” DIP-Switch
When the “BPAEN” DIP-Switch is in the “ON” (right) position,
the A Ethernet backplane port is enabled.  This port allows
connectivity to an adjacent module. When the “BPAEN”
DIP-Switch is in the “Off” position (left, factory setting), the
A port is isolated from the backplane.
Backplane B Enable “BPBEN” DIP-Switch
When the Backplane B Enable “BPBEN” DIP-Switch is in the
“ON” (right) position, the B Ethernet backplane port is enabled.
This port allows connectivity to an adjacent module.  When
the “BPBEN” DIP-Switch is in the “Off” position (left, factory
setting), the B port is isolated from the backplane.
Port 1 1000FX Auto-Negotiation  “P1 AN / MAN”
DIP-Switch
When set to the Auto-Negotiate “AN” (factory setting),
this DIP-Switch enables the Gigabit Fiber Port to sense
its duplex mode automatically.  If the connected device
cannot provide the proper signal to indicate its own
mode of operation, the P1 Manual “MAN” DIP-Switch
position should be selected to force Full-Duplex mode
on Port 1. This facilitates the connection to devices that
do not auto-negotiate properly on their Gigabit fiber port.
Note: In order for Gigabit fiber ports to link up, the
linking two devices (ports) must be set to the same
mode (either Manual or Auto-Negotiate).
When the P1 1000FX Fiber is set to Auto-Negotiation
Mode, the device receiving the fault acts as if it is in
RFD mode.
NOTE:  In older versions of firmware, RFD was not
defined on ports set to Auto-Negotiation.
Port 2 100Fx Full/Half Duplex “P2 FD / HD”
DIP-Switch
The P2 Full/Half-Duplex DIP-Switch selects the duplex
mode for the 100Mbps (FX) P2 port.  When set to
Full-Duplex “FD” (left, factory setting), the P2 port
operates in Full-Duplex mode.  When set to Half-Duplex
“HD” position (right), P2 operates in Half-Duplex mode.
NOTE:  Port 2 100FX is not defined for Auto-Negotiate
mode per the IEEE802.3 and is always in Manual mode.
UNUSED DIP-SWITCHES
The following DIP-Switches are present on the GX/F
but are unused and do not affect any functionality:
4) P2 AN/MAN
6) P2 100/10
7) P2 1000/10-100
8) P2 AX/MANX
Page 15
Page 10
Page 11
Page 12
Page 9
Page 14
Page 16
Page 13
Warning
The operating description in this Instruction Manual is for use by qualified
personnel only. To avoid electrical shock, do not perform any servicing of this
unit other than that contained in the operating instructions, unless you are
qualified and certified to do so by Omnitron Systems Technology, Inc.
Warranty
This product is warranted to the original purchaser against defects
in material and workmanship for a period of TWO YEARS from the
date of shipment. A LIFETIME warranty may be obtained by the
original purchaser by REGISTERING this product with Omnitron
within 90 days from the date of shipment. TO REGISTER,
COMPLETE AND MAIL OR FAX THE ENCLOSED
REGISTRATION FORM. You may also register your product on the
Internet at www.omnitron-systems.com. During the warranty period,
Omnitron will, at its option, repair or replace a product which is
proven to be defective.
For warranty service, the product must be sent to an Omnitron designated
facility, at Buyer’s expense. Omnitron will pay the shipping charge to
return the product to Buyer’s designated US address using Omnitron’s
standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from
improper or inadequate use and/or maintenance of the equipment by
Buyer, Buyer-supplied equipment, Buyer-supplied interfacing,
unauthorized modifications or tampering with equipment (including
removal of equipment cover by personnel not specifically authorized
and certified by Omnitron), or misuse, or operating outside the
environmental specification of the product (including but not limited to
voltage, ambient temperature, radiation, unusual dust, etc.), or improper
site preparation or maintenance.
No other warranty is expressed or implied. Omnitron specifically
disclaims the implied warranties of merchantability and fitness for
any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and exclusive
remedies. Omnitron shall not be liable for any direct, indirect,
special, incidental, or consequential damages, whether based on
contract, tort, or any legal theory.
TECHNICAL SUPPORT
For help with this product, contact our Technical Support:
Phone:
(949) 250-6510
Fax:
(949) 250-6514
Address:
Omnitron Systems Technology, Inc.
140 Technology Dr., #500
Irvine, CA 92618 USA
E-mail:
support@omnitron-systems.com
URL:
www.omnitron-systems.com
Form:  040-08560-001C   9/07
GX/F SPECIFICATIONS
MOUNTING AND CABLE ATTACHMENT
The 
iConverter
 GX/F modules are hot-swappable and
can be installed into any 
iConverter
 chassis. To install
in a chassis, perform the following steps:
1. Slide the 
iConverter
 module into the selected slot
while aligning it with the installation guides. Ensure
that  the  module is firmly seated against the
backplane.
2. Secure the module to the chassis using the panel
fastener screw (attached to the module).
3. Connect an appropriate multimode or single-mode
fiber cable to the Gigabit P1 fiber port.
4. Connect the cable to a compatible Gigabit device.
5. Connect an appropriate multimode or single-mode
fiber cable to the 100BASE-FX P2 fiber port.
6. Connect  the cable to a compatible 100BASE-FX
device.
NOTES:  Each transmit (Tx) port must connect to the
receive port of the attached device; the receive (Rx)
port must connect to the transmit port.
When using single-fiber (SF) models, the Tx wavelength
on one end must match the Rx wavelength on the other
and the converters must be used in matched pairs
(example: model 8562-05 must be matched with model
8562-07).
LED INDICATORS
LED
COLOR DESCRIPTION
Pwr:
Yellow
On--Power
F/O P1 FDX:
Green
On--Full-Duplex detected
F/O P1 Lk/Act:
Green
On--Link / Blink--activity
F/O P2 Lk/Act:
Green
On--Link / Blink--activity
F/O P2 FDX:
Green
On--Full-Duplex detected
Model Type
GX/F
Protocols
1000BASE-SX/LX,
100BASE-FX
Fiber
Connectors
SC, MT-RJ, LC, 
Single-Fiber SC
Controls
BP Enable, LS/LP, RFD,
F/O Auto/Man, 
F/O FDX/HDX
LED Displays
Power, F/O link, FDX/HDX
Dimensions
W:0.85" x D:4.5" x H:2.8"
Weight
8 oz.
Compliance
UL, CE, FCC Class A
Power
Requirement
1.5A @ 3.3VDC (typical)
Temperature
     Standard:    0 to 50º C
          Wide:    -40 to 60º C
      Storage:    -40 to 80º C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4000m
MTBF (hrs)
730,000