ERROR( Unknown Command )
Fail response, if NITZ network service is not supported 
and <time> value was more than 23 hours 59 minutes 
and 59 seconds: 
OUTPUT PULSE OFF <time>: 
ERROR( Network Time 
Missing ) 
The X refers to output pin number, 
X=1,2,3,4,5,6,7,8,9,all. 
The Y refers to either ON or OFF 
 
 
Command syntax for <time> parameter: 
<days>d<hours>h<minutes>m<seconds>s 
for example, Output_Pulse 1 On 5m30s 
Value ranges for <time> parameter: 
<time>
 
If Network Indication and Time Zone (NITZ) network service is 
supported, the range is from 1 second to 7 days.  
If NITZ network service is not supported, the range is from 1 second to 23 
hours 59 minutes and 59 seconds.  
<days>
 
If NITZ network service is supported, the range is from 1 … 7 
days.  
<hours>  
1…23 
<minutes> 1…59 
<seconds> 1…59 
Value examples for valid <time>:  
7d, 6d23h59m59s, 45m, 59s, 4h25s, 30m45s
, etc. 
Value examples for invalid <time>:  
7d1s
 
Maximum time (7 days) exceeded 
3m3m
 
There cannot be two unit fields of the same 
100s
 
Maximum second and minute value is 59. Use 1m40s instead 
24h
 
Maximum hour value is 23. Use 1d instead of 24h  
9.3.8 
Cancelling Output Pulses 
It is possible to cancel pulses before the <time> parameter defined in the pulse 
control message has passed. This is done with the “Output_Pulse_Cancel 
 
 
40/49