Omron CJ1W-EIP21 사용자 설명서
362
Connection Status Codes and Error Processing
Section 14-3
01
0316
Error code returned from target:
There was a parameter error in
the frame used to close the con-
nection.
the frame used to close the con-
nection.
This error does
not occur.
not occur.
Depends on the tar-
get’s specifications.
(Contact the target
device’s manufac-
turer.)
get’s specifications.
(Contact the target
device’s manufac-
turer.)
Depends on the orig-
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)
01
031C
Error code generated in origina-
tor:
tor:
Some other error occurred.
This error does
not occur.
not occur.
The originator gener-
ates this code when
an unsupported
response code is
returned from the
target in reply to a
connection-opening
request.
ates this code when
an unsupported
response code is
returned from the
target in reply to a
connection-opening
request.
Depends on the orig-
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)
08
---
Error code returned from target:
There is no Forward Open or
Large Forward Open service in
the target device.
Large Forward Open service in
the target device.
This error does
not occur.
not occur.
Depends on the tar-
get’s specifications.
(Contact the target
device’s manufac-
turer.)
get’s specifications.
(Contact the target
device’s manufac-
turer.)
Depends on the orig-
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)
D0
0001
Error code generated in origina-
tor:
tor:
The connection operation is
stopped.
stopped.
The connection
was stopped
because the Tag
Data Link Stop Bit
was turned ON, or
the settings data
is being down-
loaded.
was stopped
because the Tag
Data Link Stop Bit
was turned ON, or
the settings data
is being down-
loaded.
Either turn ON the
Tag Data Link
Start Bit, or wait
until the settings
data has been
downloaded.
Tag Data Link
Start Bit, or wait
until the settings
data has been
downloaded.
Includes Control-
ler stop errors,
Unit failure, and
EM bank files at
the refresh desti-
nation. To handle
these errors, refer
to 14-2-1Errors
Occurring at the
EtherNet/IP Unit
or built-in Ether-
Net/IP port.
ler stop errors,
Unit failure, and
EM bank files at
the refresh desti-
nation. To handle
these errors, refer
to 14-2-1Errors
Occurring at the
EtherNet/IP Unit
or built-in Ether-
Net/IP port.
The meaning of this
error code is defined
by each vendor, so it
depends on the tar-
get’s specifications.
(Contact the target
device’s manufac-
turer.)
error code is defined
by each vendor, so it
depends on the tar-
get’s specifications.
(Contact the target
device’s manufac-
turer.)
Depends on the orig-
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)
D0
0002
Error code generated in origina-
tor:
tor:
The connection is being opened
(opening processing in
progress).
(opening processing in
progress).
Wait until the
opening process-
ing is completed.
opening process-
ing is completed.
The meaning of this
error code is defined
by each vendor, so it
depends on the tar-
get’s specifications.
(Contact the target
device’s manufac-
turer.)
error code is defined
by each vendor, so it
depends on the tar-
get’s specifications.
(Contact the target
device’s manufac-
turer.)
Depends on the orig-
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)
inator’s specifica-
tions. (Contact the
originator device’s
manufacturer.)
Connection status
Source of error
Handling
General
Status
(hex)
Additional
Status
(hex)
Configuration 1
Configuration 2
Configuration 3