Chapter 12 Configuring SNMP 629
Nortel Secure Network Access Switch 4050 User Guide
 
addmonitor 
[<options>] -t <name
<OID> <value and 
event
>
Adds a threshold monitor and trigger as defined in the 
DISMAN-EVENT-MIB. 
Valid <
options
> are:
-c <comment>
 — adds a comment
-f <frequency>
 — the sampling interval, in 
seconds. The default is 600 (10 minutes).
-o <OID>
 — additional objects to send in the 
event
-d <OID>
 — the delta discontinuity OID
-D timeTicks|timeStamp|dateAndTime
 
— the delta discontinuity type
Other parameters are:
name
 — a unique name you assign to the monitor, 
for identification
OID
 — the object identifier (or symbolic name) to 
monitor
value and event 
— a combination of an 
integer and an event condition, where the integer 
represents the event condition threshold that will 
trigger notification. Valid combinations are:
<LowVal> FallingEvent
<HighVal> RisingEvent
<DeltaLowVal> DeltaFallingEvent
<DeltaHighVal> DeltaRisingEvent
/cfg/sys/adm/snmp/event
followed by: