Nortel Networks 4050 사용자 설명서
Chapter 12 Configuring SNMP 629
Nortel Secure Network Access Switch 4050 User Guide
addmonitor
[<options>] -t <name>
<OID> <value and
event>
[<options>] -t <name>
<OID> <value and
event>
Adds a threshold monitor and trigger as defined in the
DISMAN-EVENT-MIB.
DISMAN-EVENT-MIB.
Valid <
options
> are:
•
-c <comment>
— adds a comment
•
-f <frequency>
— the sampling interval, in
seconds. The default is 600 (10 minutes).
•
-o <OID>
— additional objects to send in the
event
•
-d <OID>
— the delta discontinuity OID
•
-D timeTicks|timeStamp|dateAndTime
— the delta discontinuity type
Other parameters are:
•
name
— a unique name you assign to the monitor,
for identification
•
OID
— the object identifier (or symbolic name) to
monitor
•
value and event
— a combination of an
integer and an event condition, where the integer
represents the event condition threshold that will
trigger notification. Valid combinations are:
represents the event condition threshold that will
trigger notification. Valid combinations are:
<LowVal> FallingEvent
<HighVal> RisingEvent
<DeltaLowVal> DeltaFallingEvent
<DeltaHighVal> DeltaRisingEvent
/cfg/sys/adm/snmp/event
followed by: