Finisar Surveyor 사용자 설명서

다운로드
페이지 454
7-28
Surveyor 
User’s Guide
The following steps describe how to create the BootPS filter template and load in to 
a resource.
1. Press the 
Clear Template
 button.
2. In the 
Apply Port to Template
 area, enter the 
Protocol 
and 
Frame Type
For the 
BootPS port, use the IP/TCP protocol. In the example, the frame type is set to 
EV2.
3. Enter the port number in decimal in the 
Apply Port to Template
 area. The 
decimal port number for BootPS is 67.
4. Pull down the 
Direction
 box and set the indicator to bi-directional (<->).
5. Be sure the 
Apply Port to Template
 check box is selected in the 
Add Port to Filter 
Template
 area. Be sure the 
Apply Conversation to Template
 check box is NOT 
selected in the 
Add Conversation to Filter Template
 area. No specific stations are 
associated with the new filter template.
6. Press the 
Save Custom Template
 button. 
7. Enter the name of the new filter template in the 
Add to Available Filter 
Templates
 dialog box. The name in the example is 
BootPS_Activity
. The new 
filter template name appears in the Custom_Templates section of the filter 
browser. 
8. Press the 
Add
 button to apply the filter template. The filter template appears in 
the 
Template Combination
 box.
9. Press the 
Load Filter
 
 button to load the filter to the resource.
10. You are now ready to start capture. The capture buffer will contain only the 
packets that contain either a source or destination BootPS port number.