Delta Electronics VFD-VL 사용자 설명서

다운로드
페이지 251
Appendix B  Accessories
B-2 
Revision Nov. 2008, VLE1, SW V1.03 
B.1 All Brake Resistors & Brake Units Used in AC Motor Drives 
Applicable 
Motor 
Voltage 
hp 
kW 
Full Load 
Torque 
Nm 
Resistor value spec 
for each AC Motor 
Drive 
Brake Torque 
10%ED 
Min. Equivalent 
Resistor Value for each 
AC Motor Drive 
7.5 5.5 
3.111 
2400W 16Ω 
125 
16Ω 
10 
7.5 
4.148 
3000W 12Ω 
125 
12Ω 
15 11 
6.186 
4800W 9Ω 
125 
9Ω 
20 
15 
8.248 
4800W 6.8Ω 
125 
6.8Ω 
25 18.5 
10.281 
6000W 6Ω 
125 
6Ω 
30 
22 
12.338 
9600W 5Ω 
125 
5Ω 
40 30 
16.497 
6000W 5Ω 
125 
5Ω 
230V Se
ries 
50 
37 
20.6 
9600W 4Ω 
125 
4Ω 
7.5 5.5 
3.111 
500W 50Ω 
125 
50Ω 
10 
7.5 
4.148 
1000W 40Ω 
125 
40Ω 
15 11 
6.186 
1000W 33Ω 
125 
33Ω 
20 
15 
8.248 
1500W 25Ω 
125 
25Ω 
25 18.5 
10.281 
4800W 21Ω 
125 
21Ω 
30 
22 
12.338 
4800W 19Ω 
125 
19Ω 
40 30 
16.497 
6000W 20Ω 
125 
20Ω 
50 
37 
20.6 
9600W 16Ω 
125 
16Ω 
60 45 
24.745 
9600W 13.6Ω 
125 
13.6Ω 
75 
55 
31.11 
12000W 10Ω 
125 
10Ω 
460V Se
ries 
100 75 
42.7 
19200W 6.8Ω 
125 
6.8Ω 
 
NOTE
 
1. 
Please select the recommended resistance value (Watt) and the duty-cycle value (ED%). 
2. 
Definition for Brake Usage ED% 
Explanation: The definition of the brake usage ED(%) is for assurance of enough time for the 
brake unit and brake resistor to dissipate away heat generated by braking. When the brake 
resistor heats up, the resistance would increase with temperature, and brake torque would 
decrease accordingly. Recommended cycle time is one minute. 
10 0%
T0
T1
Brak e Time
C yc le  Time
ED% = T1 /T0 x10 0(%)
 
3. 
For safety consideration, install an overload relay between the brake unit and the brake resistor. 
In conjunction with the magnetic contactor (MC) prior to the drive, it can perform complete 
protection against abnormality. The purpose of installing the thermal overload relay is to protect