Chapter 2 Installation and Wiring|  
Revision Nov. 2008, VLE1, SW V1.03                                                                                                                       2-9
 
„  Models above 22kW don’t have a built-in brake chopper. Please connect an external 
optional brake resistor. 
„  When not used, please leave the terminals [+2/B1, -] open. 
„  Short-circuiting [B2] or [-] to [+2/B1] can damage the AC motor drive. 
 
2.3.2 Main Circuit Terminals 
Frame C 
+/~
R/L1
S/L2
T/L3
B2
+1
DC+
DC-
EPS
/~
U/T1
V/T2
W/T3
POWER
MOTOR
+2/B1
+/~
R/L1
S/L2
T/L3
B2
+1
DC+
DC-
EPS
/~
U/T1
V/T2
W/T3
POWER
MOTOR
+2/B1
Main circuit terminals 
R/L1, S/L2, T/L3, U/T1, V/T2, W/T3, 
, +1, +2/B1, -, B2 
 
Models 
Wire 
Torque
Wire Type
VFD055VL23A
VFD110VL43A
10-6 AWG. 
(5.3-13.3mm
2
)
VFD055VL43A
VFD075VL43A
12-6 AWG. 
(3.3-13.3mm
2
)
VFD075VL23A
8-6 AWG.  
(8.4-13.3mm
2
)
VFD110VL23A
6 AWG.  
(13.3mm
2
30kgf-cm
(26in-lbf)
Stranded 
copper only, 
75
o
 
Frame D 
 
Main circuit terminals 
R/L1, S/L2, T/L3, U/T1, V/T2, W/T3, 
, +1, +2, - 
 
Models 
Wire 
Torque
Wire Type
VFD150VL43A
VFD185VL43A
8-2 AWG.  
(8.4-33.6mm
2
)
VFD150VL23A
4-2 AWG.  
(21.1-33.6mm
2
)
VFD185VL23A
3-2 AWG.  
(26.7-33.6mm
2
)
VFD220VL43A
6-2 AWG 
(13.3-33.6mm
2
)
VFD220VL23A
3-2 AWG 
(26.7-33.6mm
2
)
50Kgf-cm
(43.4 lbf-in)
Stranded 
copper only, 
75
 o