LSI Series 520 사용자 설명서

다운로드
페이지 124
 
2-10
Introduction to RAID
 Copyright © 2002 by LSI Logic Corporation. All rights reserved.
The MegaRAID SCSI 320-1 rebuild rate can be configured between 0% 
and 100%. At 0%, the rebuild is only done if the system is not doing 
anything else. At 100%, the rebuild has a higher priority than any other 
system activity.
2.3.12 Logical Drive States 
 describes the logical drive states.
2.3.13 SCSI Drive States
A SCSI disk drive can be in one of the states described in 
.
Table 2.2
Logical Drive States
State
Description
Optimal
The drive operating condition is good. All configured drives are 
online.
Degraded
The drive operating condition is not optimal. One of the 
configured drives has failed or is offline.
Failed
The drive has failed. 
Offline
The drive is not available to MegaRAID SCSI 320-1.
Table 2.3
SCSI Drive States
State
Description
Online
(ONLIN)
The drive is functioning normally and is a part of a configured 
logical drive. 
Ready
(READY)
The drive is functioning normally but is not part of a configured 
logical drive and is not designated as a hot spare.
Hot Spare
(HOTSP)
The drive is powered up and ready for use as a spare in case an 
online drive fails. 
Fail
(FAIL)
A fault has occurred in the drive, placing it out of service.
Rebuild
(REB)
The drive is being rebuilt with data from a failed drive.