Practical examples 
 
 
The script file is limited to maximum 500 characters and 12 lines. The actual 
performance will depend on the complexity of the command script. Administrators 
should reduce the redundant check as possible. Overload conditional check and heavy 
actions may retard the system operation. 
 
Command line 
Description 
MAB=1C; 
When any motion is detected on channel 1 or 2, “Normal Close” 
of relay output 1 will short with “Common”. 
1H*2\=(5)1O; 
When DI1 high companied with DI2 transient from high to low, 
“Normal Open” of relay output 1 will short with COMMON in 5 
seconds. 
B\+C\+D\=W{192.
168.0.1:6000}{no 
signal!}; 
If there is no signal on channel 2 or 3 or 4, a message “no 
signal!” will be sent to port 6000 of 192.168.0.1 once. 
2H=VAP15; 
When sensor input 2 is high, drive the camera mapped to video 
1 to go to preset location 15. 
MCD=UF+SABCD+
N{video%c%a@%
y%M%d%h%m%s
}; 
If any motion is detected on channel 3 or 4, upload snapshots 
taken on channel 1, 2, 3 and 4. If an event triggered at 19:05:30 
2002/10/15, the snapshot files will be named as, 
video1pre@20021015190530.jpg, video2pre@20021015190530.jpg 
video3pre@20021015190530.jpg, video4pre@20021015190530.jpg 
video1trg@20021015190530.jpg, video2trg@20021015190530.jpg 
video3trg@20021015190530.jpg, video4trg@20021015190530.jpg 
video1pos@20021015190531.jpg, video2pos@20021015190531.jpg 
video3pos@20021015190531.jpg, video4pos@20021015190531.jpg