Chapter 4  Configuration 
RIC-155 Installation and Operation Manual 
4-8 
Configuring the RIC-155 for Operation
 
 
Changing the Control Port Data Rate 
 
To configure the control port data rate: 
1.  From the Control Port menu, select Baud Rate
The Baud Rate menu appears (see 
2.  Select the terminal rate by typing the number corresponding to the desired 
value, and pressing <Enter>
3.  From the Control Port menu, select Save All to save the new baud rate. 
RIC-155 
Baud Rate (9600) 
1. 9600 bps 
2. 19200 bps 
3. 38400 bps 
4. 57600 bps 
5. 115200 bps 
 
Please select item <1 to 5> 
ESC-prev.menu; !-main menu; &-exit 
Figure 4-11.  Baud Rate Menu 
Configuring the Security Timeout 
The timeout specifies a time interval after which RIC-155 automatically 
disconnects from the supervisory terminal if no input from the user is detected. 
The timeout can be set to 10 minutes or disabled. 
 
To configure the security timeout: 
•  From the Control Port menu, select Security Timeout to disable it (OFF) or set 
to 10 minutes (10min). 
The display is refreshed and a new value appears. 
 
Security timeout value is not valid for the Telnet or ConfiguRAD management, 
which are permanently set to 10 minutes. 
 
Enabling and Disabling Pop-up Alarms 
When the pop-up function is enabled, RIC-155 displays alarms as they are 
generated by the system or received by the interfaces. The alarms are displayed at 
the bottom of the terminal screen.  
 
To enable or disable pop-up alarms: 
•  From the Control Port menu, select Pop Alarm to choose the pop-up alarms 
mode: ON (pop-up alarms are enabled) or OFF (pop-up alarms are disabled). 
The display is refreshed and a new value appears. 
Note