Zhone Technologies Z-PLEX-10-24-DOC-SC 사용자 설명서

다운로드
페이지 101
4-4 \ 
Zhone Technologies
Model No.
Running Head
Quick start system configuration
Configuring the Z-Plex
The first time you configure an IP address, you must reboot the system. 
4.2.1
Logging in and out of the system
You must log into the system to manage it. Note that only one administrative user can be 
logged into the Z-Plex unit at a time. The default username is “user”, the default password is 
“password”. 
For example, to log into the system:
login> user
login> ********
user>
To log out of the system, enter the logout command:
user> logout
Users are automatically logged out of the system under the following circumstances:
If a user is logged into the serial interface and another user logs in via telnet or another 
interface.
After 10 minutes, inactive sessions are automatically logged out.
4.2.2
Setting the date
Use the DATE command to set the date on the system. For example, the following command 
sets the system date to 1:30 PM, May 1, 2000:
user> SET DATE:05/01/2000 13:30:00
4.2.3
Configuring a management interface
You can configure the Z-Plex over the following interfaces:
Local 
DS0
Ethernet
IP over FDL
The following sections describe how to configure each of these interfaces.