IBM 243X 사용자 설명서

다운로드
페이지 106
nugget
 
39
 
Troubleshooting and Maintaining the Terminal
4-19
4
3. Scan the Reset Firmware label to restart the firmware and application.
Reset Firmware
*-.*
*-.*
If the terminal or application still will not respond, reset the terminal. For help, continue
with the next section.
Resetting the Terminal
If you performed the steps in “Troubleshooting a Locked Up Application” and the
terminal or application is locked up and the terminal will not respond to the Reset
Firmware command, follow the steps in this section to reset the terminal.
To reset the terminal
• Scan the Boot Terminal label to reboot the terminal.
Boot Terminal
*-.1*
*-.1*
If the terminal will not scan, you can perform a destructive reset. A destructive reset can
have unpredictable results.
1. If possible, press 
F
F to turn off the terminal.
2. Press and hold the 
F
F key for approximately 12 seconds. The Good Read LED
blinks once and the terminal turns off.
3.
 
Press 
F
F to turn on the terminal. The Boot Menu appears.
4. Press 
 to boot the terminal. Once the terminal has finished booting, your
application appears.
5. Set the time and date. For help using the TRAKKER Antares 2400 Menu System,
see “Configuring the Terminal With the Menu System” in Chapter 2.