EM78M611E
 
Universal Serial Bus Series Microcontroller
 
 
24 
•••
 
Product Specification (V1.1) 11.22.2006
 
 
(This specification is subject to change without further notice) 
 
// Set the Port 6 to input port 
MOV      A, @0xFF 
IOW       PORT6 
// Read the state of Port 6 
MOV      PORT6, PORT6 
// Clear the RUN bit 
IOR       0xE 
AND      A, 0B11101111 
IOW      0xE 
8.7.2  Dual Clock Mode 
The EM78M611E has one internal oscillator for power saving application.  Clearing the 
Bit IOCE [7] will enable the low frequency oscillator.  At the same time, the external 
oscillator will be turned off.  Then the MCU will run under very low frequency to 
conserve power.  Four types of frequency are available for selection in setting bits 
IOCA [6, 7].  
The USB Host Resume Interrupt can only be used in this mode.  If this interrupt is 
enabled, the MCU will be interrupted when the USB Host Resume signal is detected on 
USB Bus.  
8.8   Interrupt 
The EM78M611E has one interrupt vector in 0x0001.  When an interrupt occurs during 
an MCU program run, it will jump to the interrupt vector (0x0001) and execute the 
instructions sequentially from the interrupt vector.  RF is the interrupt status register, 
which records the interrupt status in the relative flags/bits. 
The interrupt condition could be one of the following:  
TCC Overflow: When the Timer Clock / Counter Register (R1) overflows, the status flag 
RF[0] will be set to 1.  Its interrupt vector is 0X0001. 
Port 7 State Change: When the input signals in Port 7 changes, the status flag RF[4] 
will be set to 1.  Its interrupt vector is 0X0001. 
SE1 Pattern Detection Interrupt Conditions: If the Pattern Detection Application 
function is enabled, there will be four conditions with which interrupt is generated, 
and the status flag RF[5] is set to 1 (interrupt vector is 0X0001). 
a)  Signal from P.92 changes to low and the Pattern Counter value is bigger than 
R11 register value.