Intel SRCSATAWB 사용자 설명서

다운로드
페이지 34
Intel® RAID Controller SRCSATAWB Hardware User’s Guide
16
Drive Migration
Drive migration moves a configured set of hard drives from one controller to another. The 
drives must remain on the same port and be reinstalled in the same order as in the original 
configuration. The controller to which you migrate the drives cannot have an existing 
configuration.
Note: Only complete configurations can be migrated; individual virtual disks cannot be 
migrated. Drive roaming and drive migration cannot be supported at the same time. 
To migrate drives:
1. Clear the configuration on the system to which you migrate the drives. This 
prevents a configuration data mismatch between the hard drives and the NVRAM.
2. Turn off the power to the system and all drives, enclosures, and system 
components. Remove the power cord(s).
3. Follow the instructions that came with your server system to remove the server 
cover.
4. Disconnect the cables from the drives to be migrated.
5. Remove the hard drives from the first system and install them into the second 
system. See your server documentation for instructions to install and remove 
drives.
6. Connect the data cables to the hard drives in the second system in the same order as 
they were connected in the first system. Make sure all the cables meet 
specifications.
7. Determine the drive target requirements.
8. Make sure all cables are properly attached and the RAID controller is properly 
installed. 
9. Follow the instructions that came with your server system to remove the server 
cover.
10. Plug in and power on the system.
When you start the system, the controller detects the RAID configuration from the 
configuration data on the drives.